Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
Accuracy of a Novel 3D‐Printed Patient‐Specific Intramedullary Guide to Control Femoral Component Rotation in Total Knee Arthroplasty
Ist Teil von
  • Orthopaedic surgery, 2020-04, Vol.12 (2), p.429-441
Ort / Verlag
Melbourne: John Wiley & Sons Australia, Ltd
Erscheinungsjahr
2020
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • Objective Total knee arthroplasty (TKA) is one of the most universal and effective means for treating terminal stage osteoarthritis (OA) of knee. Accurate intramedullary guide of femur is the basis for the distal femoral cuts. Determining the surgical transepicondylar axis (sTEA) is the key to reconstruction of the femoral rotational alignment, because the correct rotational alignment can place the femoral component in the right position, balance the flexion gap so that the inner and outer tension is equal, get stability during the flexion process of the knee, and enhance the quality of life of patients. With the development of three‐dimensional printing (3DP) technology in the medical domain, the application of patient‐specific instrumentation (PSI) in arthroplasty has become more common. The aim of this study was to evaluate the accuracy of a novel 3D‐printed patient‐specific intramedullary guide to control femoral component rotation in TKA. Methods Eighty patients (65 females and 15 males) with knee OA were included in this prospective randomized study. The patients were divided into two groups by random number table method, 40 in each group. TKA assisted by PSI (PSI group) and conventional TKA (conventional group) was performed respectively. Clinical outcomes [operation time, postoperative drainage volume, duration of drainage, Hospital for Special Surgery knee score (HSS), American Knee Society knee score (AKS)] and radiological outcomes [hip‐knee‐ankle angle (HKA), posterior condylar angle (PCA), patella transverse axis‐femoral transepicondylar axis angle (PFA), depth of intramedullary guide] were compared between and within the two groups. Results PSI group had less postoperative drainage volume but longer operation time than the conventional group (P < 0.05). The AKS and HSS scores after surgery were improved compared with those before surgery in each group (P < 0.05). However, there was no significant difference in the duration of drainage and range of motion (ROM) after surgery between the two groups. For the radiological results, the HKA and PFA were improved after surgery in both groups (P < 0.05).The postoperative PFA and PCA of the PSI group were closer to 0°, which was better than that of the conventional group (P < 0.05). The depth of intramedullary guide in the PSI group was less than the conventional group (P < 0.05). But there was no significant difference in HKA before and after surgery between the two groups as well as the preoperative PFA. Conclusion The short‐term clinical efficacy of TKA assisted by PSI was similar to the conventional TKA. Although TKA assisted by PSI spent more time during operation, it could assist in intramedullary guide and align femoral rotation more accurately.
Sprache
Englisch
Identifikatoren
ISSN: 1757-7853
eISSN: 1757-7861
DOI: 10.1111/os.12619
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_2e360300264d4455a60a9b5736f8c54d

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX