Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 9 von 63

Details

Autor(en) / Beteiligte
Titel
Implementation of the multielectrode radiofrequency-balloon in real-world clinical practice—operator learning curve and procedural outcome at a high-volume center
Ist Teil von
  • Frontiers in cardiovascular medicine, 2023-11, Vol.10, p.1208250-1208250
Ort / Verlag
Frontiers Media S.A
Erscheinungsjahr
2023
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • Background The novel multielectrode radiofrequency (RF) balloon catheter (HELIOSTAR™. Biosense Webster) is a new technology for pulmonary vein isolation (PVI) in atrial fibrillation (AF), combining RF-ablation and 3D-mapping visualization with the concept of a “single-shot”-ablation device. This study evaluates the operator learning curve und procedural outcome during implementation of the multielectrode RF-balloon at a high-volume center. Methods The first 40 patients undergoing PVI by multielectrode RF-balloon catheter at Heidelberg University Hospital were included in this prospective study. Procedural outcome was analyzed over the course of increasing experience with the device. Results 157/157 pulmonary veins (PVs) were successfully isolated with the RF-balloon catheter, in 73.2% by a single RF-application. Median time to isolation (TTI) was 11.0 s (Q1 = 8.0 s; Q3 = 13.8 s). Median procedure time was 62.5 min (Q1 = 50.0 min; Q3 = 70.5 min). LA-dwell time was 28.5 min (Q1 = 23.3 min; Q3 = 36.5 min). Median fluoroscopy duration was 11.6 min (Q1 = 10.1 min; Q3 = 13.7 min). No serious procedure-related complications were observed, apart from one case of unclear, post-procedural acute-on-chronic kidney injury. With increasing operator experience, an additional reduction in procedure duration was observed. Conclusion Rapid implementation of a “single shot”-ablation device combining RF-ablation and 3D-mapping can be achieved with high acute procedural efficacy and safety at a high-volume center. Previous experience with “single-shot” ablation devices may be advantageous for time-efficient introduction of the novel RF-balloon catheter into clinical practice. Clinical trial registration https://clinicaltrials.gov , identifier NCT05603611.
Sprache
Englisch
Identifikatoren
ISSN: 2297-055X
eISSN: 2297-055X
DOI: 10.3389/fcvm.2023.1208250
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_29aeb2dc79924881b6f1fcb8f619d567

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX