Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 99

Details

Autor(en) / Beteiligte
Titel
Measurement of D-dimer in cerebrospinal fluid using a luminescent oxygen channeling immunoassay
Ist Teil von
  • Frontiers in neurology, 2022-10, Vol.13, p.951802-951802
Ort / Verlag
Frontiers Media S.A
Erscheinungsjahr
2022
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Background Measurement of D-dimer in cerebrospinal fluid (CSF) allows insight into coagulation system activation in the central nervous system and can be utilized to monitor intracranial hemorrhage as well as acute phase processes beyond hemostasis in inflammatory and neoplastic diseases. So far, the measurability of D-dimer in low and very low concentrations in CSF was limited in conventional immunoassays. Novel high-sensitivity chemiluminescent immunoassays such as the luminescent oxygen channeling immunoassay (LOCI ® ) are getting increasingly available but have not been validated in CSF. The aim of this study was to investigate the accuracy and linearity of the LOCI ® in assessing D-dimer in CSF. Methods INNOVANCE LOCI hs D-dimer reagent cartridge was used for the measurement of D-dimer in CSF of patients with different neurological diseases. For the evaluation of linearity, dilution series were performed in a pooled CSF sample with the determination of intra-assay precision (CV, coefficient of variation) in 3 individual samples with 20 replicates. Furthermore, D-dimer concentrations measured by LOCI ® were compared with the respective results of a routinely available clinical latex-enhanced immunoassay (HemosiIL D-Dimer HS 500). Results Linear regression analysis of the LOCI ® method revealed a r 2 of 1.00 ( p < 0 .001) with a regression coefficient B of 1.012 ± 0.003 (CI: 1.005–1.019, p < 0 .001) and an intercept of −1.475 ± 1.309 (CI: −4.493 to 1.543); the median intra-assay CV was 0.69% (range: 0.68–0.75). In total, 185 CSF samples were measured by LOCI ® technology, showing a mean concentration of 204.84 ± 2,214.93 ng/ml. D-dimer concentration between LOCI and latex-enhanced immunoassay differed by a factor of 10.6 ± 13.6 on average with a maximum deviation by a factor of 61.3; the maximum deviation was found at low concentrations. Conclusion D-dimer in CSF of patients with neurological disease can be reliably measured by the LOCI ® method with high linearity and accuracy at low concentrations.
Sprache
Englisch
Identifikatoren
ISSN: 1664-2295
eISSN: 1664-2295
DOI: 10.3389/fneur.2022.951802
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_2921c9664aca445794ad66732c2e6d7f

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX