Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 9 von 26

Details

Autor(en) / Beteiligte
Titel
Reassessment of the electrical connection between the pulmonary veins and the left atrium: A study to determine the different contributions of myocardial fibers along the standard ablation circumference
Ist Teil von
  • Frontiers in cardiovascular medicine, 2023-06, Vol.10, p.1162197-1162197
Ort / Verlag
Switzerland: Frontiers Media S.A
Erscheinungsjahr
2023
Quelle
EZB Free E-Journals
Beschreibungen/Notizen
  • Circumferential ablation around the ipsilateral pulmonary veins (PVs) is the standard strategy for atrial fibrillation ablation. The present study seeks to assess which regions of the standard ablation circumference are the main contributors to the venoatrial electrical connection. A total of 41 patients were included under a specific atrial fibrillation ablation protocol in which the anterior and posterior segments of the standard circumference, between the equatorial line of the superior and the inferior ipsilateral PVs, were ablated first. If PV isolation was not achieved, ablation was extended superiorly or inferiorly, on the basis of the earliest atrial activation recorded during pacing from inside the PV. Complete PV isolation and the length of the areas not requiring ablation (ANRA) at the time of electrical isolation were evaluated. Ablation of the anterior and posterior segments of the standard circumference led to the isolation of 77% left-PV pairs and 51% right-PV pairs (  = 0,015). A superior extension was required in 23% left-PV pairs and in 46% right-PV pairs, while an inferior extension was required only in 10% left-PV pairs and in 11% right-PV pairs. PV isolation was achieved before completing the standard ablation circumference in 97% left-PV pairs and in 94% right-PV pairs, with a median ANRA of 36.9 (IQR: 30.9-42.1) mm in the left PVs [16.0 (IQR: 12.0-19.0) mm superior and 18.8 (IQR: 16.1-24.9) mm inferior,  < 0.01] and 36.9 (IQR: 30.2-41.0) mm in the right PVs [15.1 (IQR: 10.7-19.1) mm superior and 20.6 (IQR: 16.9-23.3) mm inferior,  < 0.01]. The myocardial fibers along the anterior and posterior regions of the standard ablation circumference are the main contributors to the electrical connection between the pulmonary veins and the left atrium. Ablation of these regions results in PV isolation in the majority of patients.
Sprache
Englisch
Identifikatoren
ISSN: 2297-055X
eISSN: 2297-055X
DOI: 10.3389/fcvm.2023.1162197
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_27f759b7a4434838a0cb83d6a2f9c1a6

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX