Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 87

Details

Autor(en) / Beteiligte
Titel
The influence of contralateral circulation on computational fluid dynamics of intracranial arteries: simulated versus measured flow velocities
Ist Teil von
  • European radiology experimental, 2023-09, Vol.7 (1), p.55-55, Article 55
Ort / Verlag
Vienna: Springer Vienna
Erscheinungsjahr
2023
Link zum Volltext
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • Background This study aimed to retrospectively evaluate the influence of contralateral anterior circulation on computational fluid dynamics (CFD) of intracranial arteries, by comparing the CFD values of flow velocities in unilateral anterior circulation with the measured values from phase-contrast magnetic resonance angiography (PC-MRA). Methods We analyzed 21 unilateral anterior circulation models without proximal stenosis from 15 patients who performed both time-of-flight MRA (TOF-MRA) and PC-MRA. CFD was performed with the inflow boundary condition of a pulsatile flow of the internal carotid artery (ICA) obtained from PC-MRA. The outflow boundary condition was given as atmospheric pressure. Simulated flow velocities of the middle cerebral artery (MCA) and anterior cerebral artery (ACA) from CFD were compared with the measured values from PC-MRA. Results The velocities of MCA were shown to be more accurately simulated on CFD than those of ACA (Spearman correlation coefficient 0.773 and 0.282, respectively). In four models with severe stenosis or occlusion of the contralateral ICA, the CFD values of ACA velocities were significantly lower (< 50%) than those measured with PC-MRA. ACA velocities were relatively accurately simulated in the models including similar diameters of both ACAs. Conclusion It may be necessary to consider the flow condition of the contralateral anterior circulation in CFD of intracranial arteries, especially in the ACA. Relevance statement Incorporating the flow conditions of the contralateral circulation is of clinical importance for an accurate prediction of a rupture risk in Acom aneurysms as the bidirectional flow and accurate velocity of both ACAs can significantly impact the CFD results. Key points • CFD simulations using unilateral vascular models were relatively accurate for MCA. • Contralateral ICA steno-occlusion resulted in an underestimation of CFD velocity in ACA. • Contralateral flow may need to be considered in CFD simulations of ACA. Graphical Abstract
Sprache
Englisch
Identifikatoren
ISSN: 2509-9280
eISSN: 2509-9280
DOI: 10.1186/s41747-023-00370-9
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_192104c4197748e882ff70b47f7964fd

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX