Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 20 von 295
Frontiers in bioengineering and biotechnology, 2021-05, Vol.9, p.669321-669321
2021
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Biomechanical Effects of a Cross Connector in Sacral Fractures – A Finite Element Analysis
Ist Teil von
  • Frontiers in bioengineering and biotechnology, 2021-05, Vol.9, p.669321-669321
Ort / Verlag
Frontiers Media S.A
Erscheinungsjahr
2021
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Background: Spinopelvic fractures and approaches of operative stabilization have been a source of controversial discussion. Biomechanical data support the benefit of a spinopelvic stabilization and minimally invasive procedures help to reduce the dissatisfying complication rate. The role of a cross connector within spinopelvic devices remains inconclusive. We aimed to analyze the effect of a cross connector in a finite element model (FE model). Study Design: A FE model of the L1-L5 spine segment with pelvis and a spinopelvic stabilization was reconstructed from patient-specific CT images. The biomechanical relevance of a cross connector in a Denis zone I (AO: 61-B2) sacrum fracture was assessed in the FE model by applying bending and twisting forces with and without a cross connector. Biomechanical outcomes from the numerical model were investigated also considering uncertainties in material properties and levels of osseointegration. Results: The designed FE model showed comparable values in range-of-motion (ROM) and stresses with reference to the literature. The superiority of the spinopelvic stabilization (L5/Os ilium) ± cross connector compared to a non-operative procedure was confirmed in all analyzed loading conditions by reduced ROM and principal stresses in the disk L5/S1, vertebral body L5 and the fracture area. By considering the combination of all loading cases, the presence of a cross connector reduced the maximum stresses in the fracture area of around 10%. This difference has been statistically validated ( p < 0.0001). Conclusion: The implementation of a spinopelvic stabilization (L5/Os ilium) in sacrum fractures sustained the fracture and led to enhanced biomechanical properties compared to a non-reductive procedure. While the additional cross connector did not alter the resulting ROM in L4/L5 or L5/sacrum, the reduction of the maximum stresses in the fracture area was significant.
Sprache
Englisch
Identifikatoren
ISSN: 2296-4185
eISSN: 2296-4185
DOI: 10.3389/fbioe.2021.669321
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_1116e1a4d03b45de847d5fc2e29d885b

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX