Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 11 von 725

Details

Autor(en) / Beteiligte
Titel
Online Extrinsic Calibration on LiDAR-Camera System with LiDAR Intensity Attention and Structural Consistency Loss
Ist Teil von
  • Remote sensing (Basel, Switzerland), 2022-06, Vol.14 (11), p.2525
Ort / Verlag
Basel: MDPI AG
Erscheinungsjahr
2022
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Extrinsic calibration on a LiDAR-camera system is an essential task for the advanced perception application for the intelligent vehicle. In the offline situation, a calibration object based method can estimate the extrinsic parameters in high precision. However, during the long time application of LiDAR-camera system in the actual scenario, the relative pose of LiDAR and camera has small and accumulated drift, so that the offline calibration result is not accurate. To correct the extrinsic parameter conveniently, we present a deep learning based online extrinsic calibration method in this paper. From Lambertian reflection model, it is found that an object with higher LiDAR intensity has the higher possibility to have salient RGB features. Based on this fact, we present a LiDAR intensity attention based backbone network (LIA-Net) to extract the significant co-observed calibration features from LiDAR data and RGB image. In the later stage of training, the loss of extrinsic parameters changes slowly, causing the risk of vanishing gradient and limiting the training efficiency. To deal with this issue, we present the structural consistency (SC) loss to minimize the difference between projected LiDAR image (i.e., LiDAR depth image, LiDAR intensity image) and its ground truth (GT) LiDAR image. It aims to accurately align the LiDAR point and RGB pixel. With LIA-Net and SC loss, we present the convolution neural network (CNN) based calibration network LIA-SC-Net. Comparison experiments on a KITTI dataset demonstrate that LIA-SC-Net has achieved more accurate calibration results than state-of-the-art learning based methods. The proposed method has both accurate and real-time performance. Ablation studies also show the effectiveness of proposed modules.
Sprache
Englisch
Identifikatoren
ISSN: 2072-4292
eISSN: 2072-4292
DOI: 10.3390/rs14112525
Titel-ID: cdi_doaj_primary_oai_doaj_org_article_04b5751265524d269fa16a360e7097d0

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX