Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 10 von 13
Revista española de enfermedades digestivas, 2019-03, Vol.111 (3), p.223-227
2019
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Usefulness of bioelectrical impedance analysis for monitoring patients with refractory ascites
Ist Teil von
  • Revista española de enfermedades digestivas, 2019-03, Vol.111 (3), p.223-227
Ort / Verlag
Spain: Sociedad Espanola de Patologia Digestivas
Erscheinungsjahr
2019
Quelle
MEDLINE
Beschreibungen/Notizen
  • bioelectrical impedance analysis is a technique for the determination of the hydropic component. The hydropic component, determined by blood volume, could be a reflection of the hemodynamic situation. This study aimed to evaluate the usefulness of peripheral bioelectrical impedance analysis (BIA) for the prediction of hemodynamic changes in large-volume paracentesis and prognosis. this was a proof-of-concept prospective study of 14 patients with liver cirrhosis and refractory ascites. Peripheral bioimpedance was measured three times using a portable device, IVOL®, before and after large-volume paracentesis, at different frequencies (5, 10, 20, 50, 100 and 200 kHz). Consequently, resistance, reactance and phase angle were obtained, both pre- and post-paracentesis (the difference between them was defined as Δ). the mean age of patients was 62.2 ± 9.6 years, the Child-Pugh was 8.4 ± 1.3 and the MELD score was 15.2 ± 3.9. A direct correlation between the extraction of ascitic fluid and Δresistance (10 kHz [r = 0.722; n = 12; p = 0.008], 20 kHz [r = 0.658; n = 12; p = 0.020] and 50 kHz [r = 0.519; n = 14; p = 0.057]) was observed. The presence of edema was related to lower values of both pre-paracentesis resistance (10 Hz [23.9  8 vs 32.2  4; p = 0.043]) and phase angle (5 kHz [-1.9 2.8 vs 5.9  7.3; p = 0.032]). Pre-paracentesis phase angle was directly correlated with the decline in blood pressure after paracentesis at lower frequencies (5 kHz [r = 0.694; n = 13; p = 0.008] and 10 kHz [r = 0.661; n = 13; p = 0.014]). Lower frequencies of Δphase-angle impacted on patient prognosis (5 kHz [-8.6 ± 5 vs -2.5 ± 2.7; p = 0.021]), patients with Δphase-angle 5 kHz > -4 had a higher rate of mortality (83.3% [5/6] vs 0% [0/6]; logRank 7.306, p = 0.007). Δresistance values were associated with overt HE at six months (10 kHz [4.9  2.5 vs -0.4  4.7; p = 0.046]). in conclusion, a significant correlation between peripheral impedance and hemodynamic changes was found. Impedance was also significantly related to prognosis and overt hepatic encephalopathy.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX