Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 1 von 4

Details

Autor(en) / Beteiligte
Titel
The role of micro-CT for intraoperative margin assessment of breast cancer
Ist Teil von
  • Journal of clinical oncology, 2023-06, Vol.41 (16_suppl), p.e13620-e13620
Erscheinungsjahr
2023
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • e13620 Background: Breast-conserving surgery (BCS) followed by radiotherapy requires adequate removal of the malignancy with a negative margin. Accurate pathologic margin status is not available intraoperatively and is found to be positive in up to 20% of cases, necessitating re-excision. Specimen mammography (SM), used to find a biopsy marker, may assist with margin status but is only 55% sensitive for Intraoperative margin assessment (IMA). IMA methods are being increasingly investigated. Because micro-computed tomography (micro-CT) produces three-dimensional volumetric images, we aimed to evaluate the diagnostic sensitivity of micro-CT for IMA. Methods: We performed a systematic review according to the PRISMA guidelines by querying Scopus, MEDLINE, EMBASE, PubMed, and Google Scholar through 12/21/22. (https://osf.io/342h8). Studies evaluating the applications of micro-CT scanning in breast cancer were included for systematic review, and those reporting the diagnostic indices of micro-CT for IMA compared to histopathologic results were incorporated in a study-level meta-analysis. A random effects coefficient binary regression model was used when a high level of heterogeneity was observed. Results: Of the 2920 studies, 18 studies were selected. IMA was reported in 7 studies (388 specimens), tumor size in 3 studies, microcalcifications in 12 studies, and sentinel lymph node assessment in 1 study. Half of the studies were performed in the USA; the participant’s ages ranged from 33 to 82 years, and the tumor size was between 0.8 and 55.8mm. Image procurement time ranged from 4 to 30 minutes. A pooled diagnostic sensitivity of 0.67 (95% CI: 0.48 – 0.82) and specificity of 0.75 (95% CI: 0.63 – 0.84) was revealed, and the pooled accuracy was calculated based on the normal-error estimation as 0.76 (95% CI: 0.69 – 0.83) for IMA by micro-CT compared to the histopathological evaluation. Conclusions: Micro-CT can create 3D images of the internal structure and vasculature in less than 30 minutes and detects up to 67% of positive margins intraoperatively, preventing a future reoperation. Although the results of this review are promising, due to the high level of heterogeneity, further investigations should be pursued as to how and who should report the images and whether micro-CT may have a role in IMA. [Table: see text]
Sprache
Englisch
Identifikatoren
ISSN: 0732-183X
eISSN: 1527-7755
DOI: 10.1200/JCO.2023.41.16_suppl.e13620
Titel-ID: cdi_crossref_primary_10_1200_JCO_2023_41_16_suppl_e13620
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX