Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...

Details

Autor(en) / Beteiligte
Titel
Susceptibility weighted imaging for qualitative grading of persistent arteriovenous shunting in deep-seated arteriovenous malformations after stereotactic radiation surgery
Ist Teil von
  • The neuroradiology journal, 2023-08, Vol.36 (4), p.414-420
Ort / Verlag
London, England: SAGE Publications
Erscheinungsjahr
2023
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background and purpose To investigate Susceptibility Weighted Imaging (SWI) signal changes in the draining vein of deep-seated arterio-venous malformations (AVMs) following stereotactic radiosurgery (SRS). Methods and Materials This is a retrospective study of 32 patients with deep-seated AVMs who were treated with SRS. Pre-SRS treatment and post-SRS treatment MRI were performed at 6, 12, and 24-month intervals. Deep-seated AVMs were classified based on their anatomical location and venous drainage pattern. AVM nidal volume (cm3) was estimated using the ABC/2 method. AV shunting of the AVM draining veins were graded according to its SWI signal intensity: hyperintense (grade III), mixed signal intensity (grade II), hypointense (grade I) and absent (grade 0). Conventional time-of-flight (TOF)-MRA and contrast enhanced (CE)-MRA sequences were performed to document the patency of the vein. Results Pre-SRS treatment AVM draining veins were either grade III 18/32 (56%) or grade II 14/32 (44%). Using mixed effects analysis, we demonstrate that each month following the SRS treatment nidal volumes decreased at the rate of 0.51 cm3/per month (CI −0.61 to (−0.40)) p =.00. Following the treatment, there was a clinically significant relationship between the signal and nidal volume: signal 0 corresponded with average nidal volume of 1.81 cm3 (CI 1.40–2.21), signal 1 with nidal volume of 2.06 cm3 (CI 1.69–2.44), signal 2 with nidal volume 2.73 cm3 (CI 2.35–3.11) and signal 3 with nidal volume 3.13 cm3 (CI 2.70–3.56) p = .00. Conclusion Post-SRS AVM draining veins shows a stepwise regression of the SWI signal grades which can be reliably used as a surrogate to monitor the reduction of AV shunting.
Sprache
Englisch
Identifikatoren
ISSN: 1971-4009, 2385-1996
eISSN: 2385-1996
DOI: 10.1177/19714009221140536
Titel-ID: cdi_crossref_primary_10_1177_19714009221140536

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX