Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 24 von 303

Details

Autor(en) / Beteiligte
Titel
Improving Tumor Hypoxia Location in 18 F-Misonidazole PET with Dynamic Contrast-enhanced MRI Using Quantitative Electron Paramagnetic Resonance Partial Oxygen Pressure Images
Ist Teil von
  • Radiology. Imaging cancer, 2021-03, Vol.3 (2), p.e200104
Ort / Verlag
United States
Erscheinungsjahr
2021
Quelle
Free E-Journal (出版社公開部分のみ)
Beschreibungen/Notizen
  • To enhance the spatial accuracy of fluorine 18 ( F) misonidazole (MISO) PET imaging of hypoxia by using dynamic contrast-enhanced (DCE) MR images as a basis for modifying PET images and by using electron paramagnetic resonance (EPR) partial oxygen pressure (pO ) as the reference standard. Mice ( = 10) with leg-borne MCa4 mammary carcinomas underwent EPR imaging, T2-weighted and DCE MRI, and F-MISO PET/CT. Images were registered to the same space for analysis. The thresholds of hypoxia for PET and EPR images were tumor-to-muscle ratios greater than or equal to 2.2 mm Hg and less than or equal to 14 mm Hg, respectively. The Dice similarity coefficient (DSC) and Hausdorff distance (d ) were used to quantify the three-dimensional overlap of hypoxia between pO EPR and F-MISO PET images. A training subset ( = 6) was used to calculate optimal DCE MRI weighting coefficients to relate EPR to the PET signal; the group average weights were then applied to all tumors (from six training mice and four test mice). The DSC and d were calculated before and after DCE MRI-corrected PET images were obtained to quantify the improvement in overlap with EPR pO images for measuring tumor hypoxia. The means and standard deviations of the DSC and d between hypoxic regions in original PET and EPR images were 0.35 mm ± 0.23 and 5.70 mm ± 1.7, respectively, for images of all 10 mice. After implementing a preliminary DCE MRI correction to PET data, the DSC increased to 0.86 mm ± 0.18 and the d decreased to 2.29 mm ± 0.70, showing significant improvement ( < .001) for images of all 10 mice. Specifically, for images of the four independent test mice, the DSC improved with correction from 0.19 ± 0.28 to 0.80 ± 0.29 ( = .02), and the d improved from 6.40 mm ± 2.5 to 1.95 mm ± 0.63 ( = .01). Using EPR information as a reference standard, DCE MRI information can be used to correct F-MISO PET information to more accurately reflect areas of hypoxia. Animal Studies, Molecular Imaging, Molecular Imaging-Cancer, PET/CT, MR-Dynamic Contrast Enhanced, MR-Imaging, PET/MR, Breast, Oncology, Tumor Mircoenvironment, Electron Paramagnetic Resonance © RSNA, 2021.
Sprache
Englisch
Identifikatoren
ISSN: 2638-616X
eISSN: 2638-616X
DOI: 10.1148/rycan.2021200104
Titel-ID: cdi_crossref_primary_10_1148_rycan_2021200104

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX