Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 1327
IEEE transactions on geoscience and remote sensing, 2006-07, Vol.44 (7), p.1757-1764
2006
Volltextzugriff (PDF)

Details

Autor(en) / Beteiligte
Titel
Validation of active fire detection from moderate-resolution satellite sensors: the MODIS example in northern eurasia
Ist Teil von
  • IEEE transactions on geoscience and remote sensing, 2006-07, Vol.44 (7), p.1757-1764
Ort / Verlag
New York: IEEE
Erscheinungsjahr
2006
Quelle
IEEE Xplore
Beschreibungen/Notizen
  • This paper discusses the process of validating active fire "yes/no" binary fire detection products from moderate-resolution satellite sensors. General concepts and practical issues are illustrated by the validation of the Moderate Resolution Imaging Spectroradiometer (MODIS) active fire product in Siberia. Coincident Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) imagery is used to characterize spatial patterns of flaming at sub-MODIS pixel scale. It is shown that for proper evaluation reference fire observations are needed at the scale of the satellite pixel, as only 60% of the MODIS footprints contain single contiguous clusters of ASTER fire pixels. In Siberia the size of a single ASTER fire cluster within the MODIS footprint that has a 50% probability of being flagged as "fire" is ~60, compared to ~45 in the Brazilian Amazon, whereas previous radiative transfer simulations suggested similar detection probabilities. The lower-than-expected detection rates in Siberia are largely attributable to flaming underneath heavy smoke, which is not detected by the current MODIS algorithm. Pixel-based and cluster-based omission error rates are derived, and it is shown that the probability of flagging as "fire" a MODIS pixel which contains a given number of 30-m ASTER fire pixels is typically 3-5 times lower than detecting a contiguous cluster with the same number of ASTER fire pixels. The procedures described are recommended for a consensus active fire validation protocol, but with the inclusion of multiplatform sensor configurations to complement the near-nadir angular sampling from single-platform observations such as MODIS and ASTER on Terra
Sprache
Englisch
Identifikatoren
ISSN: 0196-2892
eISSN: 1558-0644
DOI: 10.1109/TGRS.2006.875941
Titel-ID: cdi_crossref_primary_10_1109_TGRS_2006_875941

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX