Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 23 von 165

Details

Autor(en) / Beteiligte
Titel
Experiments and modelling of negative triangularity ASDEX Upgrade plasmas in view of DTT scenarios
Ist Teil von
  • Plasma physics and controlled fusion, 2024-07, Vol.66 (7), p.75013
Erscheinungsjahr
2024
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Abstract The paper presents experimental and modelling results of a comparison of negative (NT) and positive (PT) triangularity ASDEX Upgrade (AUG) discharges using the plasma shapes presently foreseen in the DTT tokamak, under construction in Italy. This work is part of a broader effort of investigation to understand whether the good properties observed in NT scenarios in DIII-D and TCV may be extrapolated to the DTT device and more generally to DEMO future operations. The experimental results have shown a practical gain of running these AUG plasmas with only ECRH and mixed NBI+ECRH phases in negative triangularity, even if they access the H-mode. Indeed, the NT electron kinetic profiles recover in all cases the PT electron pressures inside mid-radius due to reduced transport in the region ρ tor = 0.7 − 0.9 , while exhibiting lower individual ELM (Edge Localised Mode) energy losses. The ion pressure and expected fusion performance are comparable in the case of similar densities. Integrated modelling has been performed using the transport solver ASTRA and the quasi-linear turbulent model TGLF, investigating the transport properties of these discharges. The modelling reproduces the experiments qualitatively with reasonable accuracy. Nonetheless, the heat transport in NT cases is partially overestimated. This may be because TGLF uses the Miller equilibrium, which approximates the magnetic flux surfaces as up-down symmetric. In the caseof these asymmetric NT shapes, the simulated outer surfaces lose part of the tilt with respect to the z -axis, reducing the upper δ < 0 effect. A numerical test to discern the impact of the geometry by symmetrically flipping the shape has shown a beneficial effect of the negative triangularity on heat transport.
Sprache
Englisch
Identifikatoren
ISSN: 0741-3335
eISSN: 1361-6587
DOI: 10.1088/1361-6587/ad4d1c
Titel-ID: cdi_crossref_primary_10_1088_1361_6587_ad4d1c
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX