Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 22 von 124

Details

Autor(en) / Beteiligte
Titel
Improving coronary ultrafast Doppler angiography using fractional moving blood volume and motion-adaptive ensemble length
Ist Teil von
  • Physics in medicine & biology, 2022-06, Vol.67 (12), p.125021
Ort / Verlag
England: IOP Publishing
Erscheinungsjahr
2022
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Coronary microperfusion assessment is a key parameter for understanding cardiac function. Currently, coronary ultrafast Doppler angiography is the only non-invasive clinical imaging technique able to assess coronary microcirculation quantitatively in humans. In this study, we propose to use fractional moving blood volume (FMBV), proportional to the red blood cell concentration, as a metric for perfusion. FMBV compares the power Doppler in a region of interest (ROI) inside the myocardium to the power Doppler of a reference area in the heart chamber, fully filled with blood. This normalization gives then relative values of the ROI blood filling. However, due to the impact of ultrasound attenuation and elevation focus on power Doppler values, the reference area and the ROI need to be at the same depth to allow this normalization. This condition is rarely satisfied due to the cardiac anatomy. Hereby, we propose to locally compensate the attenuation between the ROI and the reference, by measuring the attenuation law on a phantom. We quantified the efficiency of this approach by comparing FMBV with and without compensation on a flow phantom. Compensated FMBV was able to estimate the ground-truth FMBV with less than 5% variation. This method was then adapted to the case of myocardial perfusion imaging during heart surgery on human neonates. The translation from to required an additional clutter filtering step to ensure that blood signals could be correctly identified in the fast-moving myocardium. We applied the singular value decomposition filter on temporal sliding windows whose lengths were a function of myocardium motion. This motion-adaptive temporal sliding window approach was able to improve blood and tissue separation in terms of contrast-to-noise ratio, as compared to well-established constant-length sliding window approaches. Therefore, compensated FMBV and singular value decomposition assisted with motion-adaptive temporal sliding windows improves the quantification of blood volume in coronary ultrafast Doppler angiography.
Sprache
Englisch
Identifikatoren
ISSN: 0031-9155
eISSN: 1361-6560
DOI: 10.1088/1361-6560/ac7430
Titel-ID: cdi_crossref_primary_10_1088_1361_6560_ac7430

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX