Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 12 von 128

Details

Autor(en) / Beteiligte
Titel
Imidazolium-based task-specific ionic liquid for selective Ag, Cu, Pd and Pt determination by means of dispersive liquid-liquid microextraction and inductively coupled plasma optical emission spectrometry
Ist Teil von
  • Spectrochimica acta. Part B: Atomic spectroscopy, 2023-06, Vol.204, p.106672, Article 106672
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2023
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • This work explores chelating capabilities of 1-butyl-2-diphenylphosphino-3-methylimidazolium hexafluorophosphate (BDPPIMPF6) as a task-specific ionic liquid (TSIL) for metal extraction/preconcentration procedures. To this end, metal extraction by BDPPIMPF6 for 21 elements (Ag, Al, As, Au, Co, Cr, Cu, Fe, Ir, Mn, Ni, Pb, Pd, Pt, Re, Rh, Ru, Sc, Ti, V, and Zn) were evaluated. This TSIL specifically forms chelating complexes with several elements of Group 10 (Pd and Pt) and Group 11 (Ag and Cu) of the Periodic Table. Chelating capabilities of BDPPIMPF6 has been exploited for developing a novel methodology for the simultaneous determination of Ag, Cu, Pd, and Pt by means of dispersive liquid-liquid microextraction and inductively coupled plasma optical emission spectrometry detection (DLLME-ICP-OES). This methodology afforded enrichment factors of 14 to 70 and limits of detection (LoD) of 0.2–2 μg L−1 for Ag, Cu, Pd and Pt. These LoD values were between 110 and 35-fold lower than those obtained by direct analyses with ICP-OES (i.e., no DLLME treatment). Finally, the proposed method has been applied to the analysis of Ag, Cu, Pd, and Pt in water and pharmaceutical products. Irrespective of matrix characteristics, quantitative recoveries were found for all the elements investigated thus highlighting methodology robustness. [Display omitted] •BDPPIMPF6 shows a great affinity for Pd and Pt (Group 10) and Ag and Cu (Group 11).•Extraction of the different elements is mainly controlled by solution pH.•A new TSIL-DLLME-based methodology has been developed with ICP-OES detection.•TSIL has been successfully applied in the analysis of water and drug samples.
Sprache
Englisch
Identifikatoren
ISSN: 0584-8547
eISSN: 1873-3565
DOI: 10.1016/j.sab.2023.106672
Titel-ID: cdi_crossref_primary_10_1016_j_sab_2023_106672

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX