Strain imaging of corroded steel fasteners using neutron transmission imaging
Ist Teil von
Measurement : journal of the International Measurement Confederation, 2022-11, Vol.203, p.111904, Article 111904
Ort / Verlag
Elsevier Ltd
Erscheinungsjahr
2022
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
•Quantitative assessment of strain in a bolt/nut assembly using neutron imaging.•Measurements for normal and corroded parts for different bolt preload conditions.•Quantitative analysis of the effect of corrosion on the loss of preloaded tension.•Quantitative analysis of the residual strain on single bolts.
Failures in bolted structural connections have caused in the past the collapse of various steel structures exposed to weather conditions, including wind turbine towers, oil and gas platforms, and bridges. Corrosion and the resulting loss of preloaded tension in the bolted connection were the root cause of such catastrophic failures in many cases. However, it is still not fully understood how strain is re-distributed in corroded bolted connections, nor how different factors influence the redistribution. Measuring non-destructively the strain inside the assembly has been the main obstacle. To this end, in this paper, we employed energy-resolved neutron transmission imaging and we present strain maps in corroded bolted connections for the first time. We examined and compared the strain distribution measurements in corroded and non-corroded assemblies for different bolt-tightening techniques. The specimens under investigation were artificially corroded without introducing any additional mechanical loads. The resulting strain maps illustrate how strain is re-distributed and provide insight into the influence of the bolt-tightening method.