Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 18 von 59

Details

Autor(en) / Beteiligte
Titel
Supported High-Risk Percutaneous Coronary Intervention With the Impella 2.5 Device
Ist Teil von
  • Journal of the American College of Cardiology, 2009-12, Vol.54 (25), p.2430-2434
Ort / Verlag
Elsevier Inc
Erscheinungsjahr
2009
Link zum Volltext
Quelle
EZB Electronic Journals Library
Beschreibungen/Notizen
  • Objectives This retrospective multicenter registry evaluated the safety and feasibility of left ventricular (LV) support with the Impella 2.5 (Abiomed Europe GmbH, Aachen, Germany) during high-risk percutaneous coronary intervention (PCI). Background Patients with complex or high-risk coronary lesions, such as last remaining vessel or left main lesions, are increasingly being treated with PCI. Because periprocedural hemodynamic compromise and complications might occur rapidly, many of these high-risk procedures are being performed with mechanical cardiac assistance, particularly in patients with poor LV function. The Impella 2.5, a percutaneous implantable LV assist device, might be a superior alternative to the traditionally used intra-aortic balloon pump. Methods The Europella registry included 144 consecutive patients who underwent a high-risk PCI. Safety and feasibility end points included incidence of 30-day adverse events and successful device function. Results Patients were older (62% >70 years of age), 54% had an LV ejection fraction ≤30%, and the prevalence of comorbid conditions was high. Mean European System for Cardiac Operative Risk Evaluation score was 8.2 (SD 3.4), and 43% of the patients were refused for coronary artery bypass grafting. A PCI was considered high-risk due to left main disease, last remaining vessel disease, multivessel coronary artery disease, and low LV function in 53%, 17%, 81%, and 35% of the cases, respectively. Mortality at 30 days was 5.5%. Rates of myocardial infarction, stroke, bleeding requiring transfusion/surgery, and vascular complications at 30 days were 0%, 0.7%, 6.2%, and 4.0%, respectively. Conclusions This large multicenter registry supports the safety, feasibility, and potential usefulness of hemodynamic support with Impella 2.5 in high-risk PCI.
Sprache
Englisch
Identifikatoren
ISSN: 0735-1097
eISSN: 1558-3597
DOI: 10.1016/j.jacc.2009.09.018
Titel-ID: cdi_crossref_primary_10_1016_j_jacc_2009_09_018

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX