Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 3 von 124

Details

Autor(en) / Beteiligte
Titel
A step forward in the equivalence between thermal and differential-flow modulated comprehensive two-dimensional gas chromatography methods
Ist Teil von
  • Journal of Chromatography A, 2020-09, Vol.1627, p.461396, Article 461396
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2020
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • •matching chromatographic performances between thermal and flow modulated GC×GC.•intuitive method translation procedure between thermal and flow modulated GC×GC.•exploring column configuration flexibility and performances in flow modulated GC×GC.•allergens profiling methods equivalence for sensitivity, linearity and accuracy. Comprehensive two-dimensional gas chromatography (GC×GC) based on flow-modulation (FM) is gaining increasing attention as an alternative to thermal modulation (TM), the recognized GC×GC benchmark, thanks to its lower operational cost and rugged performance. An accessible, rational procedure to perform method translation between the two platforms would be highly valuable to facilitate compatibility and consequently extend the flexibility and applicability of GC×GC. To enable an effective transfer, the methodology needs to ensure preservation of the elution pattern, separation power, and sensitivity. Here, a loop-type thermal modulation system with dual detection (TM-GC×GC-MS/FID) used for the targeted analysis of allergens in fragrances is selected as reference method. Initially, six different columns configurations are systematically evaluated for the flow-modulated counterpart. The set-up providing the most consistent chromatographic separation (20 m x 0.18 mm dc x 0.18 μm df + 1.8 m x 0.18 mm dc x 0.18 μm df) is further evaluated to assess its overall performance in terms of sensitivity, linearity, accuracy, and pattern reliability. The experimental results convincingly show that the method translation procedure is effective and allows successful transfer of the target template metadata. Additionally, the FM-GC×GC-MS/FID system is suitable for challenging applications such as the quantitative profiling of complex fragrance materials.
Sprache
Englisch
Identifikatoren
ISSN: 0021-9673
DOI: 10.1016/j.chroma.2020.461396
Titel-ID: cdi_crossref_primary_10_1016_j_chroma_2020_461396

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX