Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 17 von 118

Details

Autor(en) / Beteiligte
Titel
Renewing the performance of an expired particle packed column using active flow technology end fittings
Ist Teil von
  • Journal of Chromatography A, 2019-02, Vol.1586, p.145-148
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
2019
Link zum Volltext
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • •Expired Conventional HPLC columns could be renewed using Active Flow Technology.•The expired columns had reduced plate heights of 3.5.•The active flow technology renewed column had a reduced plate height less than 2.•The renewed column was better than original. The performance of a particle packed column will inevitably degrade through use or misadventure. ‘Active flow technology’ (AFT) is known to greatly improve the performance of pristine columns, but is as of yet untested when used on columns that have degraded significantly. In this study AFT was used to regenerate a degraded column, where the reduced plate height and asymmetry values were 3.5 and 1.25 respectively. Once the AFT fittings were fitted to the column outlet and the flow segmentation ratio adjusted to 28% from the radial central exit port, the reduced plate height decreased to 2.0, and the bands were almost perfectly symmetrical with asymmetry factors equal to 1.04. Subsequently, the performance of the degraded column with AFT fittings provided performance that was comparable to that of a new conventional column fitted with traditional end fittings. The separation power of the degraded conventional column and that of the same column fitted with the AFT end fittings was then tested using the separation of oligostyrenes. In AFT mode, detection was undertaken at both the radial central exit port of the column and the peripheral exit port. The resulting separation that was achieved from the radial central exit port was superior to that observed on the conventional column, whereas, the separation observed from the peripheral port was very poor. It was subsequently determined that the reason for the degraded performance of the conventional column was a result of increased heterogeneity associated with the packing material in the wall region of the column.
Sprache
Englisch
Identifikatoren
ISSN: 0021-9673
DOI: 10.1016/j.chroma.2018.12.004
Titel-ID: cdi_crossref_primary_10_1016_j_chroma_2018_12_004

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX