Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 7 von 389

Details

Autor(en) / Beteiligte
Titel
Changes in Right Ventricular Pressures Between Hemodialysis Sessions Recorded by an Implantable Hemodynamic Monitor † † Conflicts of interest: Dr Kjellström is an employee of the study sponsor. Dr Braunschweig is a consultant to the study sponsor. Dr Grandjean is an employee of the study sponsor. Dr Linde is a consultant to the study sponsor
Ist Teil von
  • The American journal of cardiology, 2009, Vol.103 (1), p.119-123
Ort / Verlag
Elsevier Inc
Erscheinungsjahr
2009
Quelle
Alma/SFX Local Collection
Beschreibungen/Notizen
  • Intermittent and chronic volume overload might contribute to the onset and progression of cardiovascular disease in patients who are undergoing maintenance hemodialysis (HD). Continuous monitoring of central hemodynamic variables may provide valuable information to improve volume control, particularly in patients with left ventricular dysfunction. Sixteen patients with end-stage renal disease who were undergoing long-term HD received an implantable hemodynamic monitor consisting of a subcutaneously implanted memory device and transvenous right ventricular (RV) lead with a pressure sensor. The implantable hemodynamic monitor continuously records heart rate, RV pressures, and estimated pulmonary arterial (PA) diastolic pressure, an estimate of left ventricular filling pressure. All patients underwent HD 3 times per week, and averages of rest hemodynamic values from the first, second, and third nights after HD during 12 weeks were analyzed. The third night always occurred after the weekend, when there was an extended interval between dialysis sessions. From the first night to the second night, RV systolic pressure increased by 10 ± 8% (p <0.001), and estimated PA diastolic pressure increased by 16 ± 14% (p <0.001). On the third night, RV systolic pressure increased by 14 ± 12% (p <0.001), and estimated PA diastolic pressure increased by 23 ± 18% (p <0.001) compared with the first night. In conclusion, the progressive pressure increments between dialysis sessions seen in this study suggest that the implantable hemodynamic monitor was a sensitive indicator for changes in volume load in patients who were undergoing HD treatment. The results also suggest that more frequent dialysis may avoid excessive pressure increase, but this needs to be investigated further in future studies.
Sprache
Englisch
Identifikatoren
ISSN: 0002-9149
eISSN: 1879-1913
DOI: 10.1016/j.amjcard.2008.08.038
Titel-ID: cdi_crossref_primary_10_1016_j_amjcard_2008_08_038
Format

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX