Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 4 von 683

Details

Autor(en) / Beteiligte
Titel
Is the incorporation of analytes into matrix crystals a prerequisite for matrix-assisted laser desorption/ionization mass spectrometry? A study of five positional isomers of dihydroxybenzoic acid
Ist Teil von
  • International journal of mass spectrometry, 1999, Vol.185, p.859-870
Ort / Verlag
Elsevier B.V
Erscheinungsjahr
1999
Link zum Volltext
Quelle
Elsevier Journal Backfiles on ScienceDirect (DFG Nationallizenzen)
Beschreibungen/Notizen
  • The 2,4-, 2,5-, 2,6-, 3,4-, and 3,5-positional isomers of dihydroxybenzoic (DHB) acid were investigated with respect to their function as matrix-assisted laser desorption/ionization (MALDI) matrices. Optical absorption spectra of solid matrix samples, recorded in diffuse reflection from samples revealed peak broadening and a red shift of the peaks relative to the solution spectra. Single crystals of all isomers were grown from solution and analyzed by x-ray crystallography. Single crystals, as well as standard dried droplet and thin layer preparations with added cytochrome c, were analyzed by UV- (266, 308, 337, 355 nm) and IR- (2.94 μm) MALDI time-of-flight mass spectrometry (MALDI-TOF-MS). A spectrophotometric measurement of the heme absorption around 400 nm of redissolved single crystals showed a quantitative incorporation of the protein into crystals of 2,5-DHB and a partial protein incorporation with large statistical fluctuations into single crystals of 2,4-DHB. No protein incorporation above the detection limit of 10 −5 molar analyte-to-matrix ratio was found for the other isomers. Best MALDI spectra from standard preparations were recorded for dried droplet preparations of 2,5-DHB at 337 and 355 nm and for 2,4-DHB at 266 and 308 nm. Both matrices performed well in the IR, too. 2,6-DHB yielded spectra of comparable quality at 337 nm and 2.94 μm, but only when prepared in a thin layer from an acetone solution. The results suggest that protein incorporation into the crystals of solid MALDI matrices is helpful, but not a prerequisite for MALDI. A large surface-to-volume ratio, typical for microcrystalline thin layer preparations supports protein desorption if no measurable incorporation occurs. Undesirable matrix adduct formation to the protein ions was seen for all DHB isomers at the wavelengths of 308 and 266 nm.
Sprache
Englisch
Identifikatoren
ISSN: 1387-3806
eISSN: 1873-2798
DOI: 10.1016/S1387-3806(98)14218-5
Titel-ID: cdi_crossref_primary_10_1016_S1387_3806_98_14218_5
Format
Schlagworte
Ion formation, MALDI-MS, Matrix effects

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX