We present the results of two beam tests performed in July and September 1996 at CERN in order to study the behaviour of irradiated single- and double-sided silicon detectors from different manufacturers. All detectors had been irradiated with neutrons, up to a maximum fluence of 3.6×1013cm−2, and had reached type inversion. Signal-to-noise ratio, resolution and efficiency have been studied for different values of detectors bias voltage, operation temperature (ranging from −10°C to +20°C) and read-out pitch and, in some case, for different incidence angle of the incoming particle. The results are promising, since no dramatic deterioration of detector performances has been observed.