Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist gegebenenfalls nur via VPN oder Shibboleth (DFN-AAI) möglich. mehr Informationen...
Ergebnis 1 von 1

Details

Autor(en) / Beteiligte
Titel
Tissue engineering of autologous aorta using a new biodegradable polymer
Ist Teil von
  • The Annals of thoracic surgery, 1999-12, Vol.68 (6), p.2298-2304
Ort / Verlag
Netherlands: Elsevier Inc
Erscheinungsjahr
1999
Link zum Volltext
Quelle
MEDLINE
Beschreibungen/Notizen
  • Background. Ovine pulmonary valve leaflets and pulmonary arteries have been tissue-engineered (TE) from autologous cells and biodegradable polyglycolic acid (PGA)-polyglactin copolymers. Use of this cell-polymer construct in the systemic circulation resulted in aneurysm formation. This study evaluates a TE vascular graft in the systemic circulation which is based on a new copolymer of PGA and polyhydroxyalkanoate (PHA). Methods. Ovine carotid arteries were harvested, expanded in vitro, and seeded onto 7-mm diameter PHA-PGA tubular scaffolds. The autologous cell-polymer vascular constructs were used to replace 3–4 cm abdominal aortic segments in lambs (group TE, n = 7). In a control group (n = 4), aortic segments were replaced with acellular polymer tubes. Vascular patency was evaluated with echography. All control animals were sacrificed when the grafts became occluded. Animals in TE group were sacrificed at 10 days (n = 1), 3 (n = 3), and 5 months (n = 3). Explanted TE conduits were evaluated for collagen content, deoxyribonucleic acid (DNA) content, structural and ultrastructural examination, mechanical strength, and matrix metalloproteinase (MMP) activity. Results. The 4 control conduits became occluded at 1, 2, 55, and 101 days. All TE grafts remained patent, and no aneurysms developed by the time of sacrifice. There was one mild stenosis at the anastomotic site after 5 months postoperatively. The percent collagen and DNA contents approached the native aorta over time (% collagen = 25.7% ± 3.4 [3 months] vs 99.6% ± 11.7 [5 months], p < 0.05; and % DNA = 30.8% ± 6.0 [3 months] vs 150.5% ± 16.9 [5 months], p < 0.05). Histology demonstrated elastic fibers in the medial layer and endothelial specific von Willebrand factor on the luminal surface. The mechanical strain-stress curve of the TE aorta approached that of the native vessel. A 66 kDa MMP-2 was found in the TE and native aorta but not in control group. Conclusions. Autologous aortic grafts with biological characteristics resembling the native aorta can be created using TE approach. This may allow the development of “live” vascular grafts.

Weiterführende Literatur

Empfehlungen zum selben Thema automatisch vorgeschlagen von bX