UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 3 von 1667
Datensatz exportieren als...
BibTeX
EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials
X-ray spectrometry, 2006-03, Vol.35 (2), p.112-115
Belikov, K. N.
Mikhailova, L. I.
Spolnik, Z. M.
Van Grieken, R.
2006
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Belikov, K. N.
Mikhailova, L. I.
Spolnik, Z. M.
Van Grieken, R.
Titel
EDXRF determination of impurities in potassium dihydrogenphosphate single crystals and raw materials
Ist Teil von
X-ray spectrometry, 2006-03, Vol.35 (2), p.112-115
Ort / Verlag
Chichester, UK: John Wiley & Sons, Ltd
Erscheinungsjahr
2006
Quelle
Wiley Blackwell Single Titles
Beschreibungen/Notizen
A fast and simple preconcentration procedure for recovering various cation impurities from potassium dihydrogenphosphate (KDP) single crystals and raw materials, followed by energy‐dispersive X‐ray fluorescence analysis (EDXRF), is described. The technique is based on the adsorption of metal 8‐hydroxyquinoline complexes from aqueous solutions of KDP on activated carbon, separation of the concentrate on a Nuclepore filter and subsequent determination by EDXRF. To fix activated carbon powder on a filter surface, an amount of 1‐hexadecanol is added to the KDP solution during the preconcentration procedure. The optimum conditions for the best recovery of the impurities were established. It was shown that a preconcentration factor of 100 can be achieved and the detection limit for a number of elements was down to 0.01 µg g−1. The relative standard deviations were 6–17% for element concentrations of 0.2 µg g−1. The method was successfully applied to the determination of Fe, Co, Cu, Ni, Zn, Mn, Ti and Bi in KDP single crystals and raw materials. Copyright © 2005 John Wiley & Sons, Ltd.
Sprache
Englisch
Identifikatoren
ISSN: 0049-8246
eISSN: 1097-4539
DOI: 10.1002/xrs.874
Titel-ID: cdi_crossref_primary_10_1002_xrs_874
Format
–
Schlagworte
Analytical chemistry
,
Chemistry
,
Exact sciences and technology
,
Spectrometric and optical methods
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX