UNIVERSI
TÄ
TS-
BIBLIOTHEK
P
ADERBORN
Anmelden
Menü
Menü
Start
Hilfe
Blog
Weitere Dienste
Neuerwerbungslisten
Fachsystematik Bücher
Erwerbungsvorschlag
Bestellung aus dem Magazin
Fernleihe
Einstellungen
Sprache
Deutsch
Deutsch
Englisch
Farbschema
Hell
Dunkel
Automatisch
Sie befinden Sich nicht im Netzwerk der Universität Paderborn. Der Zugriff auf elektronische Ressourcen ist
gegebenenfalls
nur via VPN oder Shibboleth (DFN-AAI) möglich.
mehr Informationen...
Universitätsbibliothek
Katalog
Suche
Details
Zur Ergebnisliste
Ergebnis 19 von 733
Datensatz exportieren als...
BibTeX
2D Measurement of Edge Plasma Dynamics by Using High-Speed Camera Based on HeI Line Intensity Ratio Method
Contributions to plasma physics (1988), 2010-11, Vol.50 (10), p.962-969
Ohno, N.
Miyamoto, K.
Kodama, K.
Kajita, S.
Kitagawa, K.
2010
Volltextzugriff (PDF)
Details
Autor(en) / Beteiligte
Ohno, N.
Miyamoto, K.
Kodama, K.
Kajita, S.
Kitagawa, K.
Titel
2D Measurement of Edge Plasma Dynamics by Using High-Speed Camera Based on HeI Line Intensity Ratio Method
Ist Teil von
Contributions to plasma physics (1988), 2010-11, Vol.50 (10), p.962-969
Ort / Verlag
Berlin: WILEY-VCH Verlag
Erscheinungsjahr
2010
Quelle
Wiley-Blackwell Journals
Beschreibungen/Notizen
In order to investigate dynamic plasma behaviors in scrape‐off layer (SOL) regions, such as ELMs and plasma blobs, we have developed a 4‐channel high‐speed camera equipped with four interference filters to obtain 2D successive images of spectral intensity of He I emission lines at 667.8 nm, 706.5 nm and 728.1 nm in addition to HeII at 656.0 nm. By using calculated results based on a Collisional Radiative (CR) model for He, the intensity ratios of the He I lines (728.1/706.5 and 667.8/706.5), provides 2D distributions of the electron temperature and density. The 2D profiles of electron density and temperature reconstructed from 2D images of He I emission lines taken in a small tokamak, HYBTOK‐II were compared with those measured with the triple probe in order to evaluate the accuracy of this diagnostics. Electron density and temperature measured with the 4‐channel high‐speed camera are in good agreement with those obtained with the triple probe (© 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim)
Sprache
Englisch
Identifikatoren
ISSN: 0863-1042
eISSN: 1521-3986
DOI: 10.1002/ctpp.201000030
Titel-ID: cdi_crossref_primary_10_1002_ctpp_201000030
Format
–
Schlagworte
Edge plasma
,
Edge plasma, high‐speed camera, helium line intensity ratio, plasma blob, ELM
,
ELM
,
helium line intensity ratio
,
high-speed camera
,
plasma blob
Weiterführende Literatur
Empfehlungen zum selben Thema automatisch vorgeschlagen von
bX